Related Experiment Video
Updated: Aug 9, 2026

Measuring the Mechanical Properties of Glass Fiber Reinforcement Polymer Composite Laminates Obtained by Different Fabrication Processes
Published on: June 30, 2023
Removal resistance of glass-fiber and metallic cast posts with different lengths
Neilor Mateus Antunes Braga1, Silvana Maria Paulino, Edson Alfredo
1Department of Dentistry, Ribeirão Preto School of Dentistry, University of Ribeirão Preto (UNAERP), Brazil.
Abstract:
This study evaluated the strength required to remove glass-fiber and metallic cast posts with different lengths. Sixty endodontically treated canines were included and their roots were embedded in acrylic resin after discarding the crowns. Samples were randomly assigned to 3 groups according to the post length (n = 20): I- 6 mm, II - 8 mm and III- 10 mm. Each group was divided into 2 subgroups based on the post material (n = 10): A- glass fiber or B- metallic cast. Post-space was prepared with Fibrekor Post Kit attached to a parallelometer. In subgroup A, prefabricated glass fiber posts from Fibrekor Post Kit were utilized. In metallic post group (subgroup B), an impression of post space was obtained, followed by casting. All posts were luted with Panavia F cement. A universal testing machine determined the force required to dislodge each post. ANOVA analysis indicated significant differences (P < 0.01) among post length. Tukey test showed that posts with 10 mm-length showed higher resistance on removal than posts with 6 mm-length. Posts with 8 mm-length did not exhibit difference when compared to 6 and 10 mm posts. No significant differences (P > 0.05) were observed between the tested post materials. It was concluded that the type of post did not influence the removal resistance and that posts with 10 mm-length required greater force to be dislodged.
Related Concept Videos
Fiber Reinforced Concrete
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55 °C.
Posttensioned Masonry Walls
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...
Ferrocement

