Related Experiment Video
Updated: Aug 9, 2026

Dual Test Gas Pulmonary Diffusing Capacity Measurement During Exercise in Humans Using the Single-Breath Method
Published on: February 2, 2024
Measurement of single breath-hold carbon monoxide diffusing capacity in healthy infants and toddlers
Andres Castillo1, Conrado J Llapur, Tanya Martinez
1Department of Pediatrics, Indiana University Medical Center, James Whitcomb Riley Hospital for Children, Indianapolis, Indiana 46202-5225, USA.
Abstract:
We describe a method for measuring carbon monoxide diffusing capacity (DL(CO)) and alveolar volume (V(A)) in sleeping infants, using a single 4-sec breath-hold technique. The breath-hold maneuver is obtained by inducing a respiratory pause of the respiratory system. Several inflations of the respiratory system with room air to a lung volume with an airway pressure of 30 cmH2O (V30) inhibit inspiratory effort. The respiratory system is then inflated with a test gas containing helium and a stable isotope of carbon monoxide (C18O), and a respiratory pause is maintained for 4 sec and followed by passive expiration to functional residual capacity. Concentrations of helium and C18O are continuously measured with a mass spectrometer. Twelve healthy infants between 6-22 months of age were evaluated. For 9 of 12 subjects, duplicate measurements of alveolar volume at 30 cmH2O (V(A30)) and DL(CO) were within 10%, which are the recommendations for older children and adults. Among these 9 subjects, values of V(A30) and DL(CO) increased with increasing body length (r2 = 0.82 and 0.79, respectively). The remaining 3 subjects had two values within 10-15%. Measurement of V(A) and DL(CO) with the single breath-hold technique at an elevated lung volume offers the potential to assess growth and development of the lung parenchyma early in life.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Respiratory Volumes and Capacities
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Lung Capacity