Related Experiment Video
Updated: Aug 9, 2026

Measuring Dissolved Methane in Aquatic Ecosystems Using An Optical Spectroscopy Gas Analyzer
Published on: July 26, 2024
Stacked injection with low thermal mass gas chromatography for PPB level detection of oxygenated compounds in
Jim Luong1, Ronda Gras, Hernan Cortes
1Dow Chemical Canada, P.O. BAG 16, Highway 15, Fort Saskatchewan, Alberta, Canada, T8L 2P4.
Abstract:
The presence of oxygenated compounds in light hydrocarbons can have a negative impact in manufacturing processes and on the quality of products produced. The development of an analytical technique termed "stacked injection" has been reported earlier. With this technique, sensitivity in the parts-per-billion (ppb) range for oxygenated compounds can be achieved, even with a flame ionization detector; however, there are drawbacks for this approach that limit its overall effectiveness. A new, improved analytical technique has been developed that not only addresses the shortcomings encountered, but offers markedly higher analytical performance. The new concept employs multidimensional gas chromatography (GC) with low thermal mass GC. With this new approach, throughput improvements of up to 5 times, range extension of solutes amenable for this analysis of up to nC16 alcohol, and ppb levels of detection for oxygenated compounds are achieved. Apart from alcohols, this technique is successfully employed for the ppb level analysis of other classes of oxygenated compounds, such as ethers, aldehydes, and aromatics.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
07:49On-line Analysis of Nitrogen Containing Compounds in Complex Hydrocarbon Matrixes
Published on: August 5, 2016
Related Concept Videos
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Detectors-II
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...