Intravascular radiation detectors for the detection of vulnerable atheroma
H William Strauss1, Carina Mari, Bradley E Patt
1Section of Nuclear Medicine, Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York 10021, USA. straussh@mskcc.org
Abstract:
An intravascular catheter was developed to identify inflammation in coronary atheroma. Inflammation in atheroma is associated with large numbers of macrophages. These cells have increased metabolism, increased expression of chemotactic receptors, and a high frequency of apoptosis-associated phosphatidylserine expression. Each of these parameters can be identified in vivo using specific radiolabeled agents: metabolism can be identified with 18F fluorodeoxyglucose (FDG), receptor expression with 99mTc monocyte chemotactic peptide-1, and apoptosis with 99mTc annexin V. The locally increased concentration of these tracers is readily demonstrable in experimental lesions by ex vivo autoradiography; however, the small lesion size makes it difficult to identify atheroma in the coronaries with conventional imaging equipment. In contrast, with a radiation-sensitive catheter, optimized to sense charged particle rather than gamma or x-radiation, specific lesions could be identified and localized. Charged particle radiation is emitted as a byproduct of nearly all radioactive decay but is typically most abundant in radionuclides that decay by beta emission (either positrons or negatrons). Prototype catheters, using a plastic scintillator mated to an optical fiber, have been tested in the laboratory with the positron-emitting radiopharmaceutical 18FDG. The catheter had sufficient sensitivity to detect lesions concentrating nanocurie concentrations of 18FDG. Ex vivo experiments in apo-e-/- mice confirmed the ability of the catheter to detect 18FDG in aortic lesions. These feasibility studies demonstrate the sensitivity of a beta-sensitive catheter system. Additional mechanical refinements are needed to optimize the system in anticipation of in vivo animal studies.
More Related Videos
09:43In vivo Near Infrared Fluorescence (NIRF) Intravascular Molecular Imaging of Inflammatory Plaque, a Multimodal Approach to Imaging of Atherosclerosis
Published on: August 4, 2011
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Atherosclerosis II: Clinical Manifestations and Diagnostic Tests
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT