Related Experiment Video
Updated: Aug 9, 2026

Clean Sampling and Analysis of River and Estuarine Waters for Trace Metal Studies
Published on: July 1, 2016
Signal improvement in elemental analyzer/continuous flow isotope ratio mass spectrometry for samples with low sulfur
Florian Fritzsche1, Marion Tichomirowa
1Institute of Soil Science and Soil Geography, University of Bayreuth, 95440 Bayreuth, Germany. florian.fritzsche@landw.uni-halle.de
Abstract:
Elemental analyzer/continuous flow isotope ratio mass spectrometry (EA/CF-IRMS) has become a standard procedure for the determination of delta(34)S values. Common procedures are, however, frequently less than satisfactory for organic as well as for mineral samples with very low concentrations of sulfur (<2000 ppm). Here we present a method which employs cold trapping of SO(2) to adjust the gas concentration for subsequent isotope signature determination. Analytical accuracy is comparable with common EA/CF-IRMS analysis without trapping, showing a precision of better than +/-0.4 per thousand in delta(34)S (1 SD). The virtual absence of memory effects was established by analyzing adjacent samples exhibiting a large difference in delta(34)S and by prolonged freezing of the carrier gas, yielding virtually no S concentration peak. The method was tested using less than 15% (6 microg) of the S required for a conventional isotope analysis at comparable signal intensity. Even smaller samples can be analyzed with high precision. This facilitates the on-line delta(34)S determination in small biological and mineral samples, minimizing matrix effects in various materials including sandstone, soil, and plant samples.
More Related Videos
09:31Preparation of Authigenic Pyrite from Methane-bearing Sediments for In Situ Sulfur Isotope Analysis Using SIMS
Published on: August 31, 2017
06:53Preparation of Food Samples Using Homogenization and Microwave-Assisted Wet Acid Digestion for Multi-Element Determination with ICP-MS
Published on: December 22, 2023
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Emission Spectroscopy: Overview
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Instrumentation
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...