Technical aspects of diastology: why mitral inflow and tissue Doppler imaging are the preferred parameters?
Renee L Bess1, Shahabuddin Khan, Howard S Rosman
1St. John Hospital & Medical Center, Detroit, Michigan 48236, USA. renee.bess@stjohn.org
Abstract:
Doppler methods for assessing left ventricular (LV) diastolic function have increased in number and complexity. However, time constraints may prevent measurement of all parameters during routine transthoracic echocardiography. Therefore, we designed a study to determine which Doppler parameters could be most successfully and quickly obtained. The recording success rate and time required to record different LV diastolic function parameters were evaluated in 80 patients. A specific recording protocol was followed by an experienced, credentialed sonographer and time intervals to record each parameter were measured. In comparison with color Doppler M-mode of LV inflow propagation velocities (Vp) and pulmonary venous (PV) flow measurements, transmitral valve (MV) flow and tissue Doppler imaging (TDI) of the mitral annulus had the highest recording success rate and required the shortest time to record. PV flow and Vp took longer to obtain (80.1+/-34.3 sec and 57.1+/-29.1 sec, respectively) than did mitral valve inflow (36.3+/-20.7 sec) and mitral valve annular TDI (29.3+/-18.4 sec for septal and 33.3+/-14.5 sec for lateral). MV flow velocities, Vp, and TDI were successfully recorded in virtually all patients (99-100%). In comparison, the PV flow velocities and durations were successfully recorded less often. The range of success rates for the six PV flow parameters was 49-84%. Since MV flow and TDI also have been shown by us to have the lowest interreader variability, measurement of these two parameters may be preferred for routine clinical evaluation of LV diastolic function in a busy echocardiography laboratory.
More Related Videos
12:12Echocardiographic Approaches and Protocols for Comprehensive Phenotypic Characterization of Valvular Heart Disease in Mice
Published on: February 14, 2017
08:57Pulsed Wave Doppler Assessment of Diastolic Dysfunction in the ZSF-1 Rat Model of Pulmonary Hypertension Due to Left Heart Disease
Published on: May 22, 2026
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Mitral Stenosis II: Clinical features and Diagnostic Tests