Investigation to find a suitable reference material for use as an inverse gas chromatography system suitability test
J Stapley1, G Buckton, D Merrifield
1GlaxoSmithKline, New Frontiers Science Park, Third Avenue, Harlow, Essex CM19 5AW, UK. joanne.2.stapley@gsk.com
Abstract:
The purpose of this study was to find a suitable material for use as a system suitability test material for inverse gas chromatography (IGC). The purpose of a system check is to measure the variability of the instrument being used rather than the material being analysed. Having such a system check for IGC enables a basic GMP requirement to be met. IGC results can then be used in regulatory submissions to support other already established techniques for characterising pharmaceutical materials. Alpha-alumina was chosen because it is inorganic, stable at high temperatures, resistant to hydration and is already established as a system check material for surface area determination by nitrogen adsorption. Two columns (1 and 2) packed from the same reference sample jar of alpha-alumina and analysed under the same conditions yielded dispersive surface energies of 34.8+/-0.8 and 35.3+/-0.8 mJ/m(2), respectively, at 15% RH. Column 1 was analysed on a second IGC system, and gave a dispersive surface energy of 34.7+/-0.2 mJ/m(2). No significant change was evident after 7 months storage under laboratory ambient conditions. Analysis of material from a second reference sample jar of alpha-alumina produced results not noticeably different to those of the first, yielding a dispersive surface energy of 35.3+/-0.1 mJ/m(2). A change was seen to occur in the surface properties alpha-alumina when the humidity was varied, but the change appeared to be consistent across the two columns reported. Based upon the data in this experimental, alpha-alumina appears to be a suitable material for use as a system suitability test material for IGC.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...