Related Experiment Video
Updated: Aug 8, 2026

Micron-scale Phenotyping Techniques of Maize Vascular Bundles Based on X-ray Microcomputed Tomography
Published on: October 9, 2018
Water Transport across Maize Roots : Simultaneous Measurement of Flows at the Cell and Root Level by Double Pressure
1Lehrstuhl für Pflanzenökologie, Universität Bayreuth, Universitätsstrasse 30, D-8580 Bayreuth, Federal Republic of Germany.
Abstract:
A double pressure probe technique was used to measure simultaneously water flows and hydraulic parameters of individual cells and of excised roots of young seedlings of maize (Zea mays L.) in osmotic experiments. By following initial flows of water at the cell and root level and by estimating the profiles of driving forces (water potentials) across the root, the hydraulic conductivity of individual cell layers was evaluated. Since the hydraulic conductivity of the cell-to-cell path was determined separately, the hydraulic conductivity of the cell wall material could be evaluated as well (Lp(cw) = 0.3 to 6.10(-9) per meter per second per megapascal). Although, for radial water flow across the cortex and rhizodermis, the apoplasmic path was predominant, the contribution of the hydraulic conductance of the cell-to-cell path to the overall conductance increased significantly from the first layer of the cortex toward the inner layers from 2% to 23%. This change was mainly due to an increase of the hydraulic conductivity of the cell membranes which was Lp = 1.9.10(-7) per meter per second per megapascal in the first layer and Lp = 14 to 9.10(-7) per meter per second per megapascal in the inner layers of the cortex. The hydraulic conductivity of entire roots depended on whether hydrostatic or osmotic forces were used to induce water flows. Hydrostatic Lp(r) was 1.2 to 2.3.10(-7) per meter per second per megapascal and osmotic Lp(r) = 1.6 to 2.8.10(-8) per meter per second per megapascal. The apparent reflection coefficients of root cells (sigma(s)) of nonpermeating solutes (KCI, PEG 6000) decreased from values close to unity in the rhizodermis to about 0.7 to 0.8 in the cortex. In all cases, however, sigma(s) was significantly larger than the reflection coefficient of entire roots (sigma(sr)). For KCI and PEG 6000, sigma(sr) was 0.53 and 0.64, respectively. The results are discussed in terms of a composite membrane model of the root.
More Related Videos
14:20Measuring the Osmotic Water Permeability Coefficient (Pf) of Spherical Cells: Isolated Plant Protoplasts as an Example
Published on: October 8, 2014
13:54Time-lapse Fluorescence Imaging of Arabidopsis Root Growth with Rapid Manipulation of The Root Environment Using The RootChip
Published on: July 7, 2012
Related Concept Videos
Water and Mineral Acquisition
Xylem and Transpiration-driven Transport of Resources
Short-distance Transport of Resources