Voltammetric assay of the anthelmintic veterinary drug nitroxynil in bulk form and formulation at a mercury electrode
Related Experiment Video
Updated: Aug 8, 2026

An Anaerobic Biosensor Assay for the Detection of Mercury and Cadmium
Published on: December 17, 2018
M M Ghoneim1, M El-Ries, A M Hassanein
1Chemistry Department, Faculty of Science, Tanta University, Tanta, Egypt. mmghoneim@usa.net
Abstract:
The electrochemical behavior of the anthelmintic veterinary drug nitroxynil at the mercury electrode was studied in a series of Britton-Robinson universal buffer of pH 1.9-11 containing 20% (v/v) ethanol using dc-polarography cyclic voltammetry and controlled-potential coulometry. The voltammograms exhibited two irreversible cathodic steps over the pH range 1.9-10.2; the height of the first step is double that of the second one. Controlled-potential coulometry in the B-R universal buffer of pH 1.9-10 at a mercury pool working electrode revealed the consumption of four and two electrons via the first and second reduction steps, respectively, which attributed to reduction of the NO2 group to the hydroxylamine stage (first step), and then to the amine stage (second step). Three voltammetric analytical procedures including dc-polarography, differential-pulse adsorptive stripping voltammetry and square-wave adsorptive stripping voltammetry were optimized for the direct determination of bulk nitroxynil. The three proposed procedures were applied for analysis of bulk nitroxynil with limits of detection of 3 x 10(-5), 1.31 x 10(-8) and 8.4 x 10(-10)M and limits of quantification of 1 x 10(-5), 4.36 x 10(-8) and 2.80 x 10(-9)M, respectively. The three procedures were successfully applied to the determination of nitroxynil in formulation (Dovenix, 25% nitroxynil injection solution) without the necessity for sample pretreatment and/or time-consuming extraction steps prior to the analysis.
Related Concept Videos
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Electrodeposition
Electrodeposition can...

