Related Experiment Video
Updated: Aug 8, 2026

Analyzing Mixing Inhomogeneity in a Microfluidic Device by Microscale Schlieren Technique
Published on: June 12, 2015
Improving the mixing performance of side channel type micromixers using an optimal voltage control model
Chien-Hsien Wu1, Ruey-Jen Yang
1Department of Engineering Science, National Cheng Kung University, Tainan, 70101, Taiwan.
Abstract:
Electroosmotic flow in microchannels is restricted to low Reynolds number regimes. Since the inertia forces are extremely weak in such regimes, turbulent conditions do not readily develop, and hence species mixing occurs primarily as a result of diffusion. Consequently, achieving a thorough species mixing generally relies upon the use of extended mixing channels. This paper aims to improve the mixing performance of conventional side channel type micromixers by specifying the optimal driving voltages to be applied to each channel. In the proposed approach, the driving voltages are identified by constructing a simple theoretical scheme based on a 'flow-rate-ratio' model and Kirchhoff's law. The numerical and experimental results confirm that the optimal voltage control approach provides a better mixing performance than the use of a single driving voltage gradient.
More Related Videos
Related Concept Videos
Design Example: Vintage Mixing Console
The specifications for the pre-amplifier were clear. It needed to amplify the audio signal by a factor of 10, have an input impedance above 10...
Biasing of Metal-Semiconductor Junctions
In Schottky junctions, where the semiconductor is n-type, applying a positive voltage to the metal relative to the semiconductor reduces its Fermi...
The Thermodynamics of Mixing
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...
Biasing of P-N Junction
In equilibrium, no external voltage is applied across the p-n junction. The depletion region is formed at the junction interface due to the diffusion of carriers, which leaves behind charged dopants, acceptors on the p-side, and donors on the n-side. These immobile charges create an electric field that prevents further diffusion of carriers. The related energy band...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...

