Related Experiment Video
Updated: Jul 20, 2026

In Vitro Method to Control Concentrations of Halogenated Gases in Cultured Alveolar Epithelial Cells
Published on: October 23, 2018
Inhalation induction using sevoflurane in children: the single-breath vital capacity technique compared to the tidal
C Lejus1, V Bazin, M Fernandez
1Service of Anaesthesiology, Hôtel-Dieu, CHU Nantes, France. corinne.lejus@chu-nantes.fr
Abstract:
The single-breath vital capacity technique is suitable for inhalation induction of anaesthesia, using sevoflurane in children aged > 5 years. The purpose of this randomised trial was to compare the single breath vital capacity technique with the conventional tidal volume technique. Seventy- three ASA 1 or 2 children were instructed during the pre-operative visit in the vital capacity technique. The main criterion measured was time to loss of the eyelash reflex. Induction was performed using a circle-absorber breathing circuit primed with sevoflurane 7% in 50% nitrous oxide/oxygen with 6 l.min(-1) fresh gas flow. Time required for induction, haemodynamic changes, airway tolerance and side-effects were recorded. The children's opinion on the technique used was scored using a visual analogue scale (0-100) and a Smiley scale (0-10). The time to loss of the eyelash reflex was found to be reduced in the vital capacity group compared to the tidal volume group. The time to central myosis, to achieve bispectral index values 60 and 40, haemodynamic changes, respiratory events and side-effect incidences were similar in both groups. However, we found that the vital capacity technique was preferred by the children to the tidal volume technique.
More Related Videos
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
04:16Inspiratory Muscle Training as an Adjunct to the Treatment of Weaning Failure in Critically Ill Patients: A Practical Guide
Published on: January 30, 2026
Related Concept Videos
Respiratory Volumes and Capacities I
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Inhalational Anesthetics: Overview
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Respiratory Volumes and Capacities