A dynamic method to estimate the time split between the A2 and P2 components of the S2 heart sound
1Electrical and Computer Engineering Department, University of Illinois at Chicago, USA. vnigam1@uic.edu
Abstract:
The time interval between the aortic (A2) and the pulmonary (P2) components of the second heart sound (S2) is an indicator of pulmonary arterial pressure. However, knowledge of the A2 and P2 components of the S2 sound is difficult to obtain due to their temporal overlap and significant spectral similarity. In this work, we aim to extract the A2 and P2 components from the phonocardiogram to estimate the time interval between them. We attain our objective by first isolating the S2 sound from the phonocardiogram by utilizing the mode complexity of the heart. Then, we assume the statistical independence of the A2 and P2 components and extract them from the S2 sound by the application of blind source separation techniques. Once separated, the time interval between the A2 and P2 components is estimated with a time-centroid-based method. Experimental results using simulated data show excellent performance of the proposed algorithm to extract the A2 and the P2 components from the S2 sound and to estimate the time interval between them. Results obtained from real data are also encouraging and show promise for utilizing the proposed method in a clinical setting to non-invasively tract pulmonary hypertension.
Related Concept Videos
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V) valves at the...
Beats
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation