Related Experiment Video
Updated: Aug 8, 2026

07:55
Elemental-sensitive Detection of the Chemistry in Batteries through Soft X-ray Absorption Spectroscopy and Resonant Inelastic X-ray Scattering
Published on: April 17, 2018
Surface-Sensitive XAFS in the Hard X-ray Region with Sub-Monolayer Sensitivity
Journal of Synchrotron Radiation
|March 1, 1995
Summary
This study reports surface-sensitive X-ray absorption fine structure (XAFS) with high sensitivity. The technique precisely measures surface atomic incorporation, like arsenic on InP surfaces.
Area of Science:
- Materials Science
- Surface Science
- Solid-State Physics
Background:
- Surface analysis requires techniques with high sensitivity to probe atomic-level structures.
- X-ray absorption fine structure (XAFS) is a powerful tool for elemental and structural analysis.
- Existing XAFS methods often lack the necessary sensitivity for sub-monolayer surface studies.
Purpose of the Study:
- To develop and demonstrate a highly surface-sensitive X-ray absorption fine structure (XAFS) technique.
- To enhance fluorescence detection efficiency for improved XAFS measurements.
- To apply the technique for structural characterization of surfaces and buried interfaces.
Main Methods:
- Utilized grazing-incidence fluorescence detection for surface sensitivity.
- Combined a multipole wiggler with a multi-element Si(Li) solid-state detector to boost fluorescence detection efficiency.
- Performed As K-edge XAFS studies on an InP(001) surface exposed to AsH(3).
Main Results:
- Achieved sub-monolayer sensitivity in surface XAFS measurements.
- Increased fluorescence detection efficiency by over two orders of magnitude.
- Demonstrated the incorporation of approximately 0.1 monolayer of As atoms into the InP(001) surface, substituting P atoms.
Conclusions:
- The developed grazing-incidence fluorescence XAFS technique offers exceptional surface sensitivity.
- This method is effective for structural studies of surfaces and interfaces in the hard X-ray region.
- The findings provide crucial insights into surface atomic substitution processes.
Related Concept Videos
Atomic Fluorescence Spectroscopy
Atomic fluorescence spectroscopy (AFS) is an analytical technique that involves the electronic transitions of atoms in a flame, furnace, or plasma being excited by electromagnetic (EM) radiation. When these atoms absorb energy, they become excited and subsequently release energy as they return to their original state. This emitted light, or "fluorescence," is observed at a right angle to the incident beam. Both absorption and emission processes transpire at distinct wavelengths, which are...
Atomic Absorption Spectroscopy: Lab
For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
X-ray Diffraction of Biological Samples
X-ray diffraction or XRD is an analytical tool that utilizes X-rays to study ordered structures such as crystalline organic and inorganic samples, polycrystalline materials, proteins, carbohydrates, and drugs.
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
Atomic Absorption Spectroscopy: Instrumentation
An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Radiation and Light Sources
Atomic absorption spectroscopy (AAS) relies on the Beer-Lambert law, which requires that the radiation source emits a narrow range of wavelengths to match the absorption characteristics of the analyte atom. The primary criteria for choosing an appropriate radiation source in AAS is to provide a precise and intense emission at specific wavelengths that will allow accurate detection of the analyte.
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Force Microscopy
Atomic force microscopy (AFM) is a type of scanning probe microscopy that can analyze topographic details of various specimens like ceramics, glass, polymers, and biological samples. AFM offers over 1000 times more resolution than the optical imaging system. Images generated from AFM are three-dimensional surface profiles, offering an advantage over the flat, two-dimensional images from other imaging techniques.
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...