Related Experiment Video
Updated: Aug 8, 2026

Standard Test Method ASTM D 7998-19 for the Cohesive Strength Development of Wood Adhesives
Published on: May 17, 2020
Shear bond strength of acetone-based one-bottle adhesive systems
Guilherme Carpena Lopes1, Paula C Cardoso, Luiz Clovis Cardoso Vieira
1Department of Operative Dentistry, University of Southern Santa Catarina, Tubarão, SC, Brazil. guilhermelopes@ccs.ufsc.br
Abstract:
The aim of this study was to assess the shear bond strength of four acetone-based one-bottle adhesive systems to enamel and dentin, and compare to that of an ethanol-based system used as control. Fifty human molars were bisected mesiodistally and the buccal and lingual surfaces were embedded in acrylic resin using PVC cylinders. The buccal surfaces were ground to obtain flat dentin surfaces, while the lingual surfaces were ground to obtain flat enamel surfaces. All specimens were polished up to 600-grit sandpapers and randomly assigned to 5 groups (n=20; 10 dentin specimens and 10 enamel specimens), according to the adhesive system used: One-Step (Bisco); Gluma One Bond (Heraeus Kulzer); Solobond M (Voco); TenureQuik w/F (Den-Mat) and OptiBond Solo Plus (Kerr) (control). Each adhesive system was applied according to the manufacturers' instructions. The respective proprietary hybrid composite was applied in a gelatin capsule (d=4.3 mm) and light-cured for 40 s. The specimens were tested in shear strength with an Instron machine at a crosshead speed of 5 mm/min. Bond strengths means were analyzed statistically by one-way ANOVA and Duncan's post-hoc (p< or =0.05). Shear bond strength means (MPa) (+/-SD) to enamel and dentin were: Enamel: One-Step=11.3(+/-4.9); Gluma One Bond=16.3(+/-10.1); Solobond M=18.9(+/-4.5); TenureQuik w/F=18.7(+/-4.5) and OptiBond Solo Plus=16.4(+/-3.9); Dentin: One-Step=6.4(+/-2.8); Gluma One Bond=3.0(+/-3.4); Solobond M=10.6(+/-4.9); TenureQuik w/F=7.8(+/-3.9) and OptiBond Solo Plus=15.1(+/-8.9). In enamel, the adhesive systems had statistically similar bond strengths to each other (p>0.05). However, the ethanol-based system (OptiBond Solo Plus) showed significantly higher bond strength to dentin than the acetone-based systems (p< or =0.0001). In conclusion, the solvent type (acetone or ethanol) had no influence on enamel bond strength, but had great influence on dentin bonding, which should be taken into account when choosing the adhesive system.
Related Concept Videos
Bonding and Strength of Aggregate
Physical Properties of Carboxylic Acid Derivatives
Among the carboxylic acid derivatives, the boiling points of acid chlorides and esters are very similar and are the lowest in the series. Acid anhydrides have slightly higher boiling...
Titration Calculations: Weak Acid - Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
Physical Properties of Carboxylic Acids
Acidity of 1-Alkynes
The acidic strength of hydrocarbons follows the order: Alkynes > Alkenes > Alkanes. The strength of an acid is commonly expressed in units of pKa — the lower the pKa, the stronger the acid. Among the hydrocarbons, terminal alkynes have lower pKa values and are, therefore, more acidic. For example, the pKa values for ethane, ethene, and acetylene are 51, 44, and 25, respectively, as shown here.
Anionic Chain-Growth Polymerization: Overview

