Related Experiment Video
Updated: Aug 8, 2026

Imaging Replicative Domains in Ultrastructurally Preserved Chromatin by Electron Tomography
Published on: May 20, 2022
Hard-x-ray region tomographic reconstruction of the refractive-index gradient vector field: imaging principles and
Tetsuya Yuasa1, Anton Maksimenko, Eiko Hashimoto
1Faculty of Engineering, Yamagata University, Yonezawa 992-8510, Japan. yuasa@eat72.yz.yamagata-u.ac.jp
Abstract:
The unique tomographic imaging method based on refractive effects that was recently developed by Maksimenko et al. [Appl. Phys. Lett. 86, 124105 (2005)] exhibits an excellent imaging property in the hard-x-ray region for phase objects such as soft materials and biological samples. However, there seems to have been little consideration of the physical aspects of the underlying imaging principles. Also, as the method is similar to diffraction-enhanced-imaging (DEI)-based computed tomography (CT), the difference between these two methodologies has not been made clear. We theoretically consider the imaging principles starting from the measurement process to the reconstruction procedures from the viewpoint of geometrical optics and then clarify their difference in relationship to the physical quantities to be depicted. The major feature of this novel method is the in-plane two-dimensional vector-field reconstruction of the refractive-index gradient in an object, while DEI CT obtains the out-of-plane scalar-field gradient component. In other words, the novel method and DEI CT present the transverse and the longitudinal components, respectively, of the three-dimensional vector fields of the gradient refractive index. Therefore they can be considered complementary to each other.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Imaging
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...