Related Experiment Video
Updated: Jan 24, 2026

Phase Contrast Magnetic Resonance Imaging in the Rat Common Carotid Artery
Published on: September 5, 2018
Amplifying image quality gain in x-ray phase contrast imaging of mastectomy samples with deep learning denoising
Ashkan Pakzad1, Robert Turnbull2, Simon J Mutch2
1School of Physics, The University of Melbourne, Parkville, VIC 3010, Australia.
Abstract:
Objective.Phase-contrast computed tomography (PCT) of the breast has previously been shown to produce higher-quality images at lower radiation doses without the need for breast compression. The present study is aimed at further reduction of the radiation dose in PCT, while preserving or further increasing the image quality, by applying supervised deep learning denoising of reconstructed PCT images. This work was carried out in preparation for live patient PCT breast cancer imaging, initially at specialised synchrotron facilities.Approach.PCT scans of 34 fresh full mastectomy samples were acquired using propagation-based phase-contrast imaging with 32 keV monochromatic parallel x-rays at mean glandular doses of 4 mGy and 24 mGy. All scans were reconstructed using Filtered Back Projection algorithm with Paganin's phase retrieval. A supervised U-Net-based deep learning denoising model was trained on 28 pairs of 4 mGy and 24 mGy scans and then applied to denoise the remaining 6 stacks of reconstructed 4 mGy images. Denoised PCT images were quantitatively evaluated using signal-to-noise ratio (SNR), spatial resolution, structural similarity index measure (SSIM) and peak-SNR (PSNR). The images were also visually compared and systematically assessed by experienced medical imaging specialists and radiologists.Main results.Deep learning denoising increased SNR by a factor of four while spatial resolution remained unchanged. SSIM and PSNR improved from 0.89 and 37 dB to 0.96 and 42 dB, respectively. Visual assessors significantly preferred the denoised images over the original 4 mGy images, and visual assessment indicated no increase in perceived artefacts in denoised images compared with the original 4 mGy images.Significance.Deep learning-based image denoising can further improve image quality in PCT without increasing radiation dose in imaging of mastectomies, supporting the feasibility of lower-dose PCT protocols or improved image quality for future clinical applications.
Related Concept Videos
X-ray Imaging
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...

