A multicenter study demonstrating discordant results from electronic prostate-specific antigen biochemical failure
Scott G Williams1, Tom Pickles, Larry Kestin
1Peter MacCallum Cancer Centre and University of Melbourne, Melbourne, Australia. scott.williams@petermac.org
Summary
Biochemical failure (bF) calculator results vary due to definition differences and interpretation. Developing a verification system is crucial for consistent electronic bF reporting in prostate cancer patients.
Area of Science:
- Oncology
- Medical Informatics
- Biostatistics
Background:
- Biochemical failure (bF) is a critical endpoint in prostate cancer treatment.
- Standardized electronic calculators are used to assess bF, but interobserver variation exists.
- Understanding this variation is key to accurate treatment response evaluation.
Purpose of the Study:
- To evaluate interobserver variability among four electronic biochemical failure (bF) calculators.
- To compare the concordance of three distinct bF definitions (ACD, L2, T3) across these calculators.
- To identify sources of variation in electronic bF reporting.
Main Methods:
- Analysis of data from 1200 men using four institutional electronic bF calculators.
- Comparison of bF identification using the American Society for Therapeutic Radiology and Oncology (ACD) consensus definition, the lowest PSA level to date plus 2 ng/mL (L2), and a threshold of 3 ng/mL (T3).
- Assessment of concordance and variation in bF status and timing across centers.
Main Results:
- Unanimous agreement on bF status was high: 87.3% (ACD), 96.4% (L2), and 92.7% (T3).
- Significant variation in ACD bF timing (>2 months) occurred in 270 men, with one institution contributing 63% of the variability.
- The L2 definition showed considerable timing variation (20.5%), while T3 had minimal variation (2.0%). Fifteen interpretation variations were noted.
Conclusions:
- Reported bF results are influenced by both definition differences and their implementation in electronic calculators.
- Variations in interpretation were most common for the ACD definition.
- A proposed algorithm for L2 and a verification system are needed for consistent electronic bF reporting.