Related Experiment Video
Updated: Aug 8, 2026

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
Published on: January 20, 2022
Characterization of moenomycin antibiotic complex by multistage MALDI-IT/RTOF-MS and ESI-IT-MS
Martin Zehl1, Ernst Pittenauer1, Andreas Rizzi2
1Institute of Chemical Technologies and Analytics, Vienna University of Technology, Getreidemarkt 9/164-IAC, A-1060, Vienna, Austria.
Abstract:
Flavomycin is a commercially available antimicrobial growth promoter and an authorized additive for feeding stuffs in the EU and in the USA. As most antibiotically active products biosynthesized by microorganisms, it contains not only a single active compound but is a complex mixture of structurally closely related substances. Multistage matrix-assisted laser desorption/ionization-ion trap/reflectron time-of-flight mass spectrometry (MALDI-IT/RTOF-MS) and liquid chromatography-electrospray ionization-ion trap-mass spectrometry (LC-ESI-IT-MS) were utilized for a detailed analysis of the constituents of the Flavomycin complex based on low-energy collision induced dissociation (CID). An optimal sample preparation for negative ion vacuum MALDI-MS for this compound class was developed. The MALDI-IT/RTOF-MS2 and -MS3 analysis starting with the precursor [M - H]- ions of these interesting phosphoglycolipids, named moenomycins, yielded a large variety of product ions that facilitated the structural characterization of this class of compounds. Based on the derived CID fragmentation pathway of the five known major constituents, namely moenomycin A, moenomycin A12, moenomycin C4, moenomycin C3. and moenomycin C1, four not yet described moenomycin-type constituents could be characterized. They were assigned as 4F-demethyl-6E-O-de-beta-D-glucopyranosyl-moenomycin A, 6B-N-de(2-hydroxy-5-oxo-1-cyclopenten-1-yl)-moenomycin A, 6B-hydroxy-6B-de[N-(2-hydroxy-5-oxo-1-cyclopenten-1-yl)amino]-moenomycin A, and 6C-hydroxy-moenomycin A. In addition, a moenomycin A carrying an oxygen in the moenocinol-group was found, which is most probably a chemical degradation product. These new compounds were verified by LC-ESI-IT-MS.
More Related Videos
11:04Ion Mobility-Mass Spectrometry Techniques for Determining the Structure and Mechanisms of Metal Ion Recognition and Redox Activity of Metal Binding Oligopeptides
Published on: September 7, 2019
09:24Standardized Identification of Compound Structure in Tibetan Medicine Using Ion Trap Mass Spectrometry and Multiple-Stage Fragmentation Analysis
Published on: March 17, 2023
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
MALDI-TOF Mass Spectrometry
Rapid Identification of Pathogens
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...