The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
Ultrasound-guided central venous cannulation: is there a difference between Doppler and B-mode ultrasound?
Wolfram Schummer1, Claudia Schummer, Heike Tuppatsch
1Clinic for Anesthesiology and Intensive Care Medicine, Friedrich-Schiller-University of Jena, Germany. cwsm.schummer@gmx.de
Study Objective:
To compare the success of Doppler and B-mode ultrasound-guided internal jugular vein (IJV) catheterization with respect to body mass index (BMI).
Study Design:
Prospective, randomized study.
Setting:
Section for cardiovascular anesthesia of a university hospital.
Patients:
338 consenting patients were analyzed.
Interventions:
Subjects receiving central venous catheters for scheduled cardiac surgery were divided into two groups. After induction of general anesthesia, the right or left IJV was assessed for midcervical cannulation approach. In the Doppler group (n = 189), a SonoGuide2 with a 5.0-MHz probe was used. In the B-mode group (n = 149), the SiteRite II ultrasound system with a 7.5-MHz transducer was used.
Measurements And Main Results:
There was a significant difference in the success rate of first needle pass between the two groups: Doppler group, 91% (172/189); B-mode group, 96.6% (144/149) (P = 0.045). A BMI of 30 and greater was associated with a significantly lower first needle pass success rate in the Doppler group (Doppler group, 77.1% [27/35]; B-mode group, 97.4% [38/39]; P = 0.011). The success rates in patients with a BMI below 30 for both methods were not different (Doppler group, 94.2% [145/154]; B-mode group, 96.4% [106/110]; P = 0.567). Arterial punctures occurred three times under Doppler guidance and twice under B-mode guidance.
Conclusion:
Cannulation of the IJV can be ensured and first needle pass success rate maximized by both ultrasound techniques. In patients with a BMI greater than 30, B-mode technique is superior to Doppler ultrasound.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Imaging Studies II: Ultrasonography