Assessment of the practical role of a radionuclide low-fat-meal solid gastric emptying study
Vani Vijayakumar1, Elma G Briscoe, Theresa L Boysen
1Nuclear Medicine Section, Department of Radiology, University of Texas Medical Branch, Galveston, Texas 77555, USA. vavijaya@utmb.edu
Unlabelled:
The aim of this study was to assess the practical role of a low-fat-meal gastric emptying protocol and its effect on a patient's compliance and comfort, number of patient referrals, daily nuclear medicine scheduling, patient throughput, and cost-effectiveness.
Methods:
We retrospectively reviewed the charts of patients who underwent low-fat-meal gastric emptying studies between February 2003 and February 2004. The study was approved by the University of Texas Medical Branch institutional review board.
Results:
A total of 117 studies were identified. There were 36 males and 81 females. A total of 36 patients had prolonged gastric emptying (30.8%), and 5 patients had rapid emptying (4.3%). The test meal was well tolerated by 112 of 117 patients (95.8%); 5 patients were unable to complete the meal (4.3%).
Conclusion:
We found that patient tolerance, compliance, and comfort with the low-fat-meal gastric emptying protocol were excellent, increasing the number of patient referrals. In addition, the low-fat-meal protocol can accommodate more patients and hence can be beneficial for busy nuclear medicine sections with a necessity for high patient volumes; the protocol also is cost-effective.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...