Effect of endotracheal suction on lung dynamics in mechanically-ventilated paediatric patients
Brenda Morrow1, Merle Futter, Andrew Argent
1Physiotherapy Department, Red Cross War Memorial Children's Hospital, Cape Town, South Africa. bmorrow@ich.uct.ac.za
Insights
Endotracheal suctioning in ventilated children often decreases lung compliance and tidal volume, potentially causing lung volume loss. This common procedure does not appear to reduce airway resistance.
Area of Science:
- Pediatric Critical Care Medicine
- Respiratory Physiology
- Mechanical Ventilation
Background:
- Endotracheal suctioning is a routine procedure for ventilated infants and children to clear airway secretions.
- The impact of endotracheal suctioning on respiratory mechanics in this population is not well understood.
Purpose of the Study:
- To investigate the immediate effects of endotracheal suctioning on dynamic lung compliance, tidal volume, and airway resistance.
- To assess changes in respiratory mechanics in mechanically ventilated pediatric patients following a standardized suctioning protocol.
Main Methods:
- A prospective observational clinical study was conducted on 78 mechanically ventilated pediatric patients.
- Lung mechanics were measured for five minutes before and after a standardized endotracheal suctioning procedure.
- Patients with significant endotracheal tube leaks (>= 20%) were excluded from the analysis.
Main Results:
- A significant decrease in dynamic lung compliance (p < 0.001) and expired tidal volume (p = 0.03) was observed post-suctioning.
- No significant change in endotracheal tube leak percentage (p = 0.41) or airway resistance (p > 0.05) was found.
- The reduction in dynamic compliance correlated with endotracheal tube and catheter sizes.
Conclusions:
- Endotracheal suctioning frequently leads to an immediate reduction in dynamic compliance and tidal volume in ventilated children.
- This suggests a potential loss of lung volume associated with the suctioning procedure.
- The study found no evidence that endotracheal suctioning decreases airway resistance.
Abstract:
Endotracheal suctioning is performed regularly in ventilated infants and children to remove obstructive secretions. The effect of suctioning on respiratory mechanics is not known. This study aimed to determine the immediate effect of endotracheal suctioning on dynamic lung compliance, tidal volume, and airway resistance in mechanically-ventilated paediatric patients by means of a prospective observational clinical study. Lung mechanics were recorded for five minutes before and five minutes after a standardised suctioning procedure in 78 patients intubated with endotracheal tubes < or = 4.0 mm internal diameter. Twenty-four patients with endotracheal tube leaks > or = 20% were excluded from analysis. There was a significant overall decrease in dynamic compliance (p < 0.001) and mechanical expired tidal volume (p = 0.03) following suctioning with no change in the percentage endotracheal tube leak (p = 0.41). The change in dynamic compliance was directly related to both endotracheal tube and catheter sizes. There was no significant change in expiratory or inspiratory airway resistance following suctioning (p > 0.05). Although the majority of patients (68.5%) experienced a drop in dynamic compliance following suctioning, dynamic compliance increased in 31.5% of patients after the procedure. This study demonstrates that endotracheal suctioning frequently causes an immediate drop in dynamic compliance and expired tidal volume in ventilated children with variable lung pathology, intubated with small endotracheal tubes, probably indicating loss of lung volume caused by the suctioning procedure. There is no evidence that suctioning reduces airway resistance.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Tracheostomy Suctioning II: Procedure
Mechanical Ventilation I: Indication and Settings
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Suctioning the Nasopharyngeal Airway
Equipment Required