Related Experiment Video
Updated: Aug 7, 2026

04:59
Rotating the Intraocular Lens to Prevent Posterior Capsular Opacification in Cataract Surgeries
Published on: July 7, 2023
Two-string technique to manage dislocated posterior chamber plate-haptic intraocular lens
Mohammad Fayez Rahim1, Boris Malyugin
1Department of Cataract and Implant Surgery, S. Fyodorov Eye Microsurgery Complex Federal State Institution, Moscow, Russia. faizrh@yahoo.com
Journal of Cataract and Refractive Surgery
|June 13, 2006
Summary
This study presents a novel technique for repositioning dislocated plate-haptic foldable collamer posterior chamber intraocular lenses (PC IOLs). The described method offers a viable alternative to lens removal or exchange for managing displaced PC IOLs.
Area of Science:
- Ophthalmology
- Surgical Techniques
- Intraocular Lenses
Background:
- Dislocation of posterior chamber intraocular lenses (PC IOLs) can occur, necessitating intervention.
- Management options for dislocated PC IOLs traditionally include lens removal or exchange.
- Plate-haptic foldable collamer PC IOLs present unique challenges when dislocated.
Purpose of the Study:
- To describe a novel technique for the repositioning and transscleral fixation of a dislocated plate-haptic foldable collamer PC IOL.
- To provide an alternative surgical approach to avoid IOL explantation or replacement.
- To detail the specific steps involved in the transscleral fixation procedure.
Main Methods:
- The dislocated PC IOL was repositioned from the anterior chamber.
- A double-armed suture on a curved needle was used for fixation.
- Scleral fixation was performed at specific clock hours (10:30, 4:30, 7:30) passing through the superior haptic eyelet and mirroring the path for the inferior haptic.
Main Results:
- Successful repositioning and transscleral fixation of the dislocated PC IOL were achieved.
- The described technique allowed for secure placement of the IOL without removal.
- The fixation method provided stable positioning through symmetrical suture placement.
Conclusions:
- The described transscleral fixation technique is a potentially useful alternative for managing dislocated plate-haptic foldable collamer PC IOLs.
- This method may offer a less invasive approach compared to IOL exchange or removal.
- Further studies may be warranted to evaluate the long-term outcomes and efficacy of this technique.