Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Time and sample site dependency of the optimized co-rebreathing method
Christopher J Gore1, Pitre C Bourdon, Sarah M Woolford
1Department of Physiology, Australian Institute of Sport, Canberra, AUSTRALIA. chris.gore@ausort.gov.au
Purpose:
A new method to estimate hemoglobin mass (Hbmass) requires capillary blood and rebreathing a carbon-monoxide (CO) bolus for 2 min. We hypothesized that incomplete circulatory mixing of CO could confound this method, so we compared capillary with venous blood to determine whether sampling site altered the percentage of carboxyhemoglobin (%HbCO) and the reliability and accuracy of the "2-min Hbmass." The conventional 20-min CO-rebreathing procedure was used as the Hbmass criterion.
Methods:
In the first experiment (N=12), both fingertip capillary and antecubital venous blood were sampled 4 and 6 min after commencing 2 min of CO-rebreathing. Within 8 d, these subjects completed two 2-min and one 20-min CO-rebreathing periods. For the latter, capillary and venous blood were collected simultaneously after two 10-min periods of rebreathing. In a second experiment (N=6), both capillary and venous blood were sampled 4, 6, 8, 10, and 12 min after commencing 2 min of CO-rebreathing. A third experiment (N=6) evaluated the reliability of a modified 2-min CO-rebreathing test with capillary blood sampled at minutes 8 and 10.
Results:
Typical error (TE) for the first two 2-min tests was 1.1% (90% confidence limits 0.9-1.8%), but the average Hbmass from 2-min capillary blood was 4.8% lower than from venous blood for the 20-min procedure. In the second experiment, peak venous %HbCO occurred at minute 6, and the difference between capillary and venous values was minimal (mean+/-SD; 0.08+/-0.07, 0.01+/-0.09) at minutes 8 and 10. TE for the third experiment was 1.2% (0.8-2.5%).
Conclusion:
A modified 2-min CO-rebreathing procedure using capillary or venous blood sampled 8 and 10 min after starting CO-rebreathing allows complete circulatory mixing and provides an accurate and reliable estimate of Hbmass.
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...