Related Experiment Video
Updated: Aug 7, 2026

Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
[Preliminary clinical study of microimplants in the restoration of edentulous jaws]
1Center of Implant Dentistry, Peking University School and Hospital of Stomatology, Beijing 100081, China. MD_CHENBO@sina.com
Objective:
To investigate if magnetic- attached overdenture supported by microimplants of 2.5 mm in diameter was able to function properly.
Methods:
Fourteen microimplants were placed in 4 patients. Implants were exposed 3 months later and magnetic abutments were connected directly. X-ray was taken during the 3 year follow-up to examine marginal bone level. Peri-implant soft tissue was also checked. Denture retention, chewing stability and overall satisfaction with the microimplants retained overdenture were evaluated.
Results:
All of the 14 microimplants achieved initial primary stability without infection or any other postoperative complications. No implant was lost during the follow-up period. Only one magnetic abutment fractured one year after restoration and was replaced. X-ray showed highly stable marginal bone level around the microimplants. The patients were satisfied with the restoration.
Conclusions:
The microimplants retained overdenture leads to a significant improvement of function despite of the small dimensions of these implants. In particular for elder patients with severe residual ridge resorption, this treatment represents a less invasive alternative compared to conventional implant systems.