Three Dimensional Vestibular Ocular Reflex Testing Using a Six Degrees of Freedom Motion Platform
Published on: May 23, 2013
[Application of a jaw motion tracking device that measures six degrees of freedom using optoelectronic]
Takumi Ogawa1, Yuko Shigeta, Eriko Ando
1The Second Department of Prosthetic Dentistry, Tsurumi University School of Dentistry. ogawa-t@tsurumi-u.ac.jp
Purpose:
A jaw motion tracking device that measures six degrees of freedom has recently been developed. Understanding jaw motion is useful, but previous measurement methods were impractical for use in dental clinics. The overall aim of this study was to demonstrate the simple operation, low cost, and high precision of a recently developed jaw tracking device. In addition, this study explored its potential clinical applications.
Methods:
In this study, we compared two jaw motion tracking devices: a digital system type of device and an optical type of device. First we established a baseline occlusal plane from which to measure jaw motion in the same subject with both devices. The jaw motion signals were sampled at a frequency of 100 Hz. The subjects were three healthy women (mean age +/- SD = 26.3 +/- 1.2 years) who were recruited from among the crown-and-bridge faculty of Tsurumi University of Dentistry. The jaw motions measured were open-close movement, sagittal border movement, and frontal border movement. In addition, the kinematic axis point was calculated from the sagittal border movement. Data from the digital system type of device and data from the optical device were compared. The data were selected to measure rotation and translocation, i.e. jaw position about protrusion, both laterotrusion and maximal opening of the mouth.
Results:
The root mean square (RMS) error of position measurement was 0.163 mm with MM-JI-E and 0.178 mm with the optical type of device. The RMS error of jaw motion measurement with the optical type of device was maximum at 0.8mm and minimum at 0.1mm. This was similar to that with digital system type of jaw motion tracking device.
Conclusion:
This study showed the possibility of developing clinical applications for this jaw motion device.
More Related Videos
08:48Combining Multiple Data Acquisition Systems to Study Corticospinal Output and Multi-segment Biomechanics
Published on: January 9, 2016
07:24Using Eye-tracking to Assess the Relative Importance of Visual and Vestibular Input to Subcortical Motion Processing in the Roll Plane
Published on: August 22, 2025
Related Concept Videos
Gyroscope
Gyroscope: Precession
One-Degree-of-Freedom System
A one-degree-of-freedom system is defined by an independent variable that determines its state and behavior. One example of a one-degree-of-freedom system is a simple harmonic oscillator, such as a...
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the drone...
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it instrumental in...
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...