Related Experiment Video
Updated: Aug 7, 2026

Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
Using multi-walled carbon nanotubes as solid phase extraction adsorbents to determine dichlorodiphenyltrichloroethane
Qingxiang Zhou1, Junping Xiao, Weidong Wang
1School of Chemistry and Environmental Sciences, Henan Normal University, Henan Key Laboratory for Environmental Pollution Control, Xinxiang 453007, China. zhouqx@henannu.edu.cn
Abstract:
Carbon nanotubes (CNTs) are a kind of new carbon-based nano-materials which have drawn great attention in many application fields. The potential of multi-walled carbon nanotubes (MWNTs) as solid-phase extraction (SPE) adsorbents for the preconcentration of environmental pollutants has been investigated in recent years. The goal of this work was to investigate the feasibility of MWNTs used as SPE adsorbents to enrich dichlorodiphenyltrichloroethane (DDT) and its metabolites including 1,1-dichloro-2,2-bis-(4'-chlorophenyl)ethane (DDD) and 1,1-dichloro-2,2-bis-(4'-chlorophenyl)ethane (DDE) at trace level which are typical persistent organic pollutants in environment. Parameters that maybe influence the extraction efficiency such as the eluent volume, sample flow rate, sample pH and the sample volume were optimized in detail. The experimental results showed the excellent linear relationship between peak area and the concentration of DDT and its metabolites over the range of 0.2-60 microg L(-1), and the precisions (RSD) were 2.3-2.5% under the optimal conditions. The detection limits of proposed method could reach 4-13 ng L(-1) based on the ratio of chromatographic signal to base line noise (S/N = 3). Satisfied results were achieved when the proposed method was applied to determine the four target compounds in realworld water samples with spiked recoveries over the range of 89.7-115.5%. All these facts indicated that MWCNTs as SPE packing materials coupled to HPLC was an excellent alternative for the routine analysis of DDT and its metabolites at trace level in environment.
More Related Videos
07:32Detection of 3-Nitrotyrosine in Atmospheric Environments via a High-performance Liquid Chromatography-electrochemical Detector System
Published on: January 30, 2019
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II