Chemically imaging living cells by scanning electrochemical microscopy

Allen J Bard1, Xiao Li, Wei Zhan

  • 1Department of Chemistry and Biochemistry, The University of Texas at Austin, Austin, TX 78712, United States. asn@mail.utexas.edu

Summary

Scanning electrochemical microscopy (SECM) offers high-resolution analysis of biological interfaces. This technique effectively monitors cellular processes and detects electroactive substances in living cells and cell models.

Related Concept Videos

Scanning Electron Microscopy01:07

Scanning Electron Microscopy

A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
Overview of Electron Microscopy01:25

Overview of Electron Microscopy

The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
Immunogold Electron Microscopy01:20

Immunogold Electron Microscopy

Immunoelectron microscopy utilizes immunogold labeling of endogenous proteins with specific antibodies to detect and localize these proteins in cells and tissues. The procedure provides insights into the distribution and quantification of protein under different stimulation conditions offering clues about their functions. Conjugating highly electron-dense gold particles with primary or secondary antibodies allow antigen detection on and within cells, with high resolution and specificity.
Cryo-electron Microscopy01:28

Cryo-electron Microscopy

Conventional electron microscopy (EM) involves dehydration, fixation, and staining of biological samples, which distorts the native state of biological molecules and results in several artifacts. Also, the high-energy electron beam damages the sample and makes it difficult to obtain high-resolution images. These issues can be addressed using cryo-EM, which uses frozen samples and gentler electron beams. The technique was developed by Jacques Dubochet, Joachim Frank, and Richard Henderson, for...
Three-Dimensional Microscopy in Microbiology01:28

Three-Dimensional Microscopy in Microbiology

Three-dimensional imaging techniques are essential in cell biology, allowing researchers to visualize intricate cellular structures with high resolution. Two prominent methods, Differential Interference Contrast Microscopy (DIC) and Confocal Scanning Laser Microscopy (CSLM), provide distinct advantages for imaging live and thick specimens, respectively.Differential Interference Contrast MicroscopyDIC microscopy enhances contrast in transparent, unstained samples by converting phase...
Preparation of Samples for Electron Microscopy01:20

Preparation of Samples for Electron Microscopy

To be visualized by an electron microscope, either transmission or scanning, biological samples need to be fixed (stabilized) so the electron beam does not destroy them and dried thoroughly (desiccated/dehydrated) so the vacuum does not affect them. Fixation needs to be done as quickly as possible because the sample properties will start changing as soon as it is removed from its natural environment. For example, in a tissue sample, the oxygen levels begin decreasing, causing an altered...