Related Experiment Video
Updated: Jul 30, 2026

16:23
Automated, Quantitative Cognitive/Behavioral Screening of Mice: For Genetics, Pharmacology, Animal Cognition and Undergraduate Instruction
Published on: February 26, 2014
Undermatching and overmatching: The fixed-ratio changeover requirement
Journal of the Experimental Analysis of Behavior
|July 1, 1981
Summary
Behavioral economics research shows that varying the number of responses required to switch between options influences choice patterns. Findings suggest that undermatching or overmatching can be achieved by adjusting these changeover requirements.
Area of Science:
- Behavioral psychology
- Animal behavior studies
- Operant conditioning
Background:
- Matching law in behavioral economics predicts response distribution based on reinforcement schedules.
- Previous research indicated overmatching with higher changeover requirements (5-10 responses).
Purpose of the Study:
- To investigate the effect of lower fixed-ratio changeover requirements (1, 2, 4 responses) on concurrent schedules.
- To determine if undermatching or overmatching can be systematically produced by varying changeover requirements.
Main Methods:
- Concurrent variable-interval schedules (2-min and 6-min) were used.
- The fixed-ratio changeover requirement was manipulated (1, 2, or 4 responses).
- Response and time allocation data were analyzed.
Main Results:
- A 4-response requirement led to overmatching in both response and time data.
- A 1-response requirement resulted in undermatching in time data, with mixed response data.
- A 2-response requirement showed undermatching in time data and overmatching in response data.
Conclusions:
- Matching is not a fixed outcome; it is sensitive to changeover requirements.
- Systematic variation of changeover requirements can produce either undermatching or overmatching.
- Findings extend previous research and suggest a continuum of matching behavior based on response requirements.
Related Concept Videos
Controller Configurations
Controller configurations are crucial in a car's cruise control system because they manage speed over time to maintain a consistent pace regardless of road conditions, thereby meeting design goals. In traditional control systems, fixed-configuration design involves predetermined controller placement. System performance modifications are known as compensation.
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller aligns...
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller aligns...
Transformers with Off-Nominal Turns Ratios
In scenarios involving parallel transformers with disparate ratings, developing per-unit models requires accommodating off-nominal turns ratios. This situation arises when the selected base voltages are not proportional to the transformer’s voltage ratings. Consider a transformer where the rated voltages are related by the term a. If the chosen voltage bases satisfy a relationship involving term b, term c is defined as the ratio of these bases. This ratio is then substituted into the rated...
Radial System Protection
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Reclosers and Fuses
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
Multimachine Stability
Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Load-frequency control
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...

