Onset of non-linearity in zonal elution separators: the concept of effective analyte concentration
1Laboratoire de Physique et Mécanique des Milieux Hétérogènes, UMR CNRS 7636, Ecole Supérieure de Physique et de Chimie Industrielles, 10 rue Vauquelin, 75231 Paris Cedex 05, France. martin@pmmh.espci.fr
Abstract:
When an analyte injected in a zonal separation method (chromatography, capillary zone electrophoresis, field-flow fractionation) is not highly diluted in the carrier fluid, the retention ratio, R--or ratio of the cross-sectional average migration velocity of the analyte to that of the carrier fluid--depends on the local concentration, c, of the center of mass of the analyte zone, and the zone migration occurs in non-linear conditions. Because the zone broadens as it moves along the separator, R varies continuously from the inlet to the outlet of the separator. That concentration, c(eff), for which R(c(eff)) is equal to the length-averaged apparent retention ratio, R(app), is called effective concentration, and that distance, z(eff), from the separator inlet, for which c(z(eff)) is equal to c(eff), i.e. for which R(z(eff)) is equal to R(app), is called effective position. Assuming that near the onset the non-linear behavior, R(c), is a linear function, values of R(app), c(eff) and z(eff) have been computed in a wide range of operating conditions which are typical of situations encountered in capillary zone electrophoresis, liquid chromatography, or field-flow fractionation. Computations have been performed both in presence and in absence of the dispersion arising from the concentration dependence of the analyte migration rate (called thermodynamic dispersion in chromatography or electromigration dispersion in capillary zone electrophoresis). It is found that, whatever the range of analyte concentration covered from inlet to outlet of the separator, c(eff) is always close to two times the analyte concentration, c(out), at the outlet of the separator, and z(eff) between one-fourth and one-third of the separator length. As c(out) is easily determined from the peak recorded by a concentration-sensitive detector, a simple pragmatic expression is given for the estimation of c(eff). This effective concentration is the appropriate concentration to be used for comparing predictions of theoretical models of R(c) with experimental retention data. This is of particular interest for validating such models in field-flow fractionation.
More Related Videos
Related Concept Videos
Analyte Adsorption and Distribution
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
High-Performance Liquid Chromatography: Elution Process
Ion-Exchange Chromatography
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...