Related Experiment Video
Updated: Jan 30, 2026

In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023
Flexion after total knee replacement. A comparison between the Medial Pivot knee and a posterior stabilised implant
David Shakespeare1, Michael Ledger, Vera Kinzel
1Warwickshire Nuffield Hospital, Old Milverton Lane, Leamington Spa, Warwickshire CV32 6RW, UK. davidshakespeare@uk-consultants.co.uk
Abstract:
A comparison was made between 261 knees replaced with the Medial Pivot arthroplasty and 288 replaced with the 913 posterior stabilised arthroplasty (PS knee). There was no significant difference in the flexion obtained at 12 months after surgery (111 degrees and 109 degrees , respectively). When the knees were grouped into preoperative flexion ranges, there was no significant difference between the two implants. Those knees with preoperative flexion up to 90 degrees gained most (mean 22.6 degrees and 19 degrees for the PS knee and Medial Pivot, respectively). Knees with a preoperative flexion of 125 degrees or greater lost flexion. Regression analysis of individual knees revealed a small (average 2.9 degrees ), but significant greater loss of flexion at 12 months after surgery in the Medial Pivot group, with increasing preoperative flexion (beta coefficient = 2.923, P = 0.007). Some knees in both groups which had less than average preoperative flexion lost rather than gained flexion. We attributed this to patient factors such as pain, swelling and poor compliance with rehabilitation. Although the Medial Pivot knee may have advantages in terms of contact area and kinematics we found no advantage in terms of postoperative flexion over our posterior stabilised knee.
Related Concept Videos
Continuous Renal Replacement Therapy
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Pivot Bearings
A pivot bearing is a specialized type of bearing designed to support axial loads on a rotating shaft. The bearing surface, or the pivot, is positioned at the end of a shaft to support the axial thrust. The pivot may...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons