Solvent and temperature gradients in separation of synthetic oxyethylene-oxypropylene block (co)polymers using
Tomasz Welerowicz1, Pavel Jandera, Katerina Novotná
1Department of Environmental Chemistry and Ecoanalytics, Faculty of Chemistry, Nicholas Copernicus University, Torun, Poland.
Abstract:
Chromatographic behavior of synthetic block (co)oligomer samples (EO)n(PO)m(EO)n and (PO)n(EO)m(PO)n with different distribution of propylene oxide (PO) and ethylene oxide (EO) monomer units was investigated on three types of stationary phases on zirconium dioxide support: Zr-PS (polystyrene), Zr-carbon, and Zr-carbon C18. The effects of the distribution and sequence of the oxyethylene and oxypropylene monomer units on the chromatographic retention depend on the type of the stationary phase, but are strongly affected by the organic modifier (methanol or ACN) in aqueous-organic mobile phase. Special attention was focused on the influence of the mobile-phase composition on the separation according to the EO and PO distribution. Zirconia-based columns are stable at elevated temperatures and can be used in high-temperature LC (HTLC); hence, we investigated the temperature effects on the chromatographic behavior up to 90 degrees C. The applications of solvent and temperature gradients were compared on the zirconia stationary phases in the RP mode.
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...