Related Experiment Video
Updated: Aug 7, 2026

Dynamic Electrochemical Measurement of Chloride Ions
Published on: February 5, 2016
A new method for calculation of the chlorine demand of natural and treated waters
Ben Warton1, Anna Heitz, Cynthia Joll
1Centre for Applied Organic Geochemistry, Curtin University of Technology, GPO Box U1987, Perth WA 6845, Australia. B.Warton@curtin.edu.au
Abstract:
Conventional methods of calculating chlorine demand are dose dependent, making intercomparison of samples difficult, especially in cases where the samples contain substantially different concentrations of dissolved organic carbon (DOC), or other chlorine-consuming species. Using the method presented here, the values obtained for chlorine demand are normalised, allowing valid comparison of chlorine demand between samples, independent of the chlorine dose. Since the method is not dose dependent, samples with substantially differing water quality characteristics can be reliably compared. In our method, we dosed separate aliquots of a water sample with different chlorine concentrations, and periodically measured the residual chlorine concentrations in these subsamples. The chlorine decay data obtained in this way were then fitted to first-order exponential decay functions, corresponding to short-term demand (0-4h) and long-term demand (4-168 h). From the derived decay functions, the residual concentrations at a given time within the experimental time window were calculated and plotted against the corresponding initial chlorine concentrations, giving a linear relationship. From this linear function, it was then possible to determine the residual chlorine concentration for any initial concentration (i.e. dose). Thus, using this method, the initial chlorine dose required to give any residual chlorine concentration can be calculated for any time within the experimental time window, from a single set of experimental data.
More Related Videos
10:00Experimental Protocol to Determine the Chloride Threshold Value for Corrosion in Samples Taken from Reinforced Concrete Structures
Published on: August 31, 2017
08:49Vegetated Treatment Systems for Removing Contaminants Associated with Surface Water Toxicity in Agriculture and Urban Runoff
Published on: May 15, 2017
Related Concept Videos
Calculating Equilibrium Concentrations
A more...
Electrolysis
Testing Water Quality
Titration Calculations: Weak Acid - Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Chemical Equilibria: Systematic Approach to Equilibrium Calculations
The first step is to identify all the chemical reactions involved, The...