A highly selective potentiometric sensor of molybdate based on a mu-oxo-bridged manganeseporphyrin dimer

Zheng-Hui Fang1, Zhi-Xiang Han, Xiao-Bing Zhang

  • 1State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry & Chemical Engineering, Hunan University, Changsha 410082, P.R. China.

Related Concept Videos

Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at the...
Potentiometry: Overview01:06

Potentiometry: Overview

Potentiometry is an analytical technique that measures the potential difference between two electrodes in an electrochemical cell without drawing any significant current that could alter the solution's composition. This method employs an indicator electrode, which exchanges electrons with the analyte solution, and a reference electrode with a constant potential. Each electrode is immersed in a solution comprised of two half-cells. In a conventional setup, the reference electrode serves as the...
Potentiometry: Types of Electrodes01:19

Potentiometry: Types of Electrodes

Reference electrodes serve as a stable reference point for potentiometric measurements, while indicator and working electrodes react to variations in the composition of a solution.
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Controlled-Potential Coulometry: Electrolytic Methods01:17

Controlled-Potential Coulometry: Electrolytic Methods

Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential ensures...
Redox Titration: Other Oxidizing and Reducing Agents01:26

Redox Titration: Other Oxidizing and Reducing Agents

Besides iodine, other oxidizing or reducing agents can serve as titrants in redox titrations. Common oxidizing titrants include KMnO4, cerium(IV), and K2Cr2O7. The choice of oxidizing titrants depends on factors like stability, cost, analyte strength, and reaction rate between the analyte and titrant. KMnO4 is a strong oxidizing titrant that reduces from Mn(VII) to Mn(II) in a highly acidic solution, simultaneously oxidizing the analyte to a higher oxidation state. In this case, KMnO4 acts as a...
Complexometric Titration: Overview00:39

Complexometric Titration: Overview

Complexometric titration involves the formation of a complex by reacting a metal ion with one or more ligands. A visual indicator often detects the end point of a complexometric titration. It is added to the metal solution before the titration, forming a stable metal–indicator complex and imparting color to the solution. As the titration approaches the equivalence point, the excess of the added ligand displaces the indicator from the metal–indicator complex, releasing the free indicator. The...