Auxiliary probe design adaptable to existing probes for remote detection NMR, MRI, and time-of-flight tracing
Songi Han1, Josef Granwehr, Sandra Garcia
1University of California Berkeley, Department of Chemistry, Lawrence Berkeley National Laboratory, Material Sciences Divisions, Berkeley, CA 94720, USA. songi@chem.ucsb.edu
Abstract:
A versatile, detection-only probe design is presented that can be adapted to any existing NMR or MRI probe with the purpose of making the remote detection concept generally applicable. Remote detection suggests freeing the NMR experiment from the confinement of using the same radio frequency (RF) coil and magnetic field for both information encoding and signal detection. Information is stored during the encoding step onto a fluid sensor medium whose magnetization is later measured in a different location. The choice of an RF probe and magnetic field for encoding can be made based solely on the size and characteristics of the sample and the desired information quality without considering detection sensitivity, as this aspect is dealt with by a separate detector. While early experiments required building probes that included two resonant circuits, one for encoding and one for detection, a modular approach with a detection-only probe as presented here can be used along with any existing NMR probe of choice for encoding. The design of two different detection-only probes is presented, one with a saddle coil for milliliter-sized detection volumes, and the other one with a microsolenoid coil for sub-microliter fluid quantities. As example applications, we present time-of-flight (TOF) tracing of hyperpolarized (129)Xe spins in a gas mixture through coiled tubing using the microsolenoid coil detector and TOF flow imaging through a nested glass container where the gas flow changes its direction twice between inlet and outlet using the saddle coil detector.
Related Concept Videos
Mass Analyzers: Common Types
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Applications Of NMR In Biology
The...
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
NMR Spectrometers: Overview
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...