A randomized, prospective study comparing the use of the missile trocar and the pyramidal trocar for laparoscopy
Tanvaa Tansatit1, Wirach Wisawasukmongchol, Suvit Bunyavejchevin
1Department ofAnatomy, Faculty of Medicine, King Chulalongkorn Memorial Hospital, Chulalongkorn University, Bangkok, Thailand.
Background:
The missile trocar was developed for smooth abdominal penetration of the primary port. It contains a longitudinal tunnel connecting the abdominal cavity with the outside.
Objective:
To evaluate the efficacy of the missile trocar compared with the traditional method using the Veress needle.
Material And Method:
The times required to enter the abdominal cavity and the difficulty of the procedure were compared with the traditional Veress needle. A blind technique was used on 100 consecutive patients in a randomized fashion.
Results:
The missile trocar technique took 2.7 +/- 1.6 minutes to perform compared with 3.9 +/- 1.3 min in the Veress needle group (p = 0.001), and the difficulty of the procedure was 2.1 +/- 1.9 cm (p = 0.433) rated from 10-cm scale. No carbon dioxide leakage or serious complications occurred in any patient.
Conclusion:
The results of the present study indicate that a long-tip missile trocar technique may be used safely when the technique is fully understood. This procedure is a relatively quick alternative approach for laparoscopy.