Related Experiment Video
Updated: Aug 6, 2026

07:10
A Sectioning, Coring, and Image Processing Guide for High-Throughput Cortical Bone Sample Procurement and Analysis for Synchrotron Micro-CT
Published on: June 12, 2020
CT-guided bone biopsy: Initial experience with a commercially available hand held Black and Decker drill
O Buckley1, W Benfayed, T Geoghegan
1Department of Radiology, The Adelaide and Meath, Hospital, Tallaght, Dublin 24, Ireland.
European Journal of Radiology
|August 8, 2006
Summary
A commercial hand drill effectively performs CT-guided bone biopsies, showing high technical success and minimal complications. This method offers a feasible approach for obtaining diagnostic bone samples.
Area of Science:
- Medical Imaging
- Orthopedic Surgery
- Interventional Radiology
Background:
- CT-guided bone biopsies are crucial for diagnosing bone pathologies.
- Traditional methods may involve specialized equipment, potentially increasing costs and complexity.
Purpose of the Study:
- To evaluate the efficacy and safety of using a readily available commercial hand drill for CT-guided bone biopsies.
- To assess the technical feasibility, diagnostic yield, and complication rates of this adapted technique.
Main Methods:
- A specially designed adapter enabled connection of standard bone biopsy kits to a commercial hand drill.
- Musculoskeletal radiologists at three international institutions performed CT-guided bone biopsies using the adapted drill.
- Data on technical success, diagnostic yield, and complications were collected over a 3-year period.
Main Results:
- Sixty-eight patients underwent CT-guided bone biopsy with the commercial drill.
- Technical success was achieved in 65 patients (95.6%).
- Diagnostic material was obtained in 53 patients (77.9%), with no major complications reported.
Conclusions:
- CT-guided bone biopsy using a commercial hand drill is a technically successful and safe procedure.
- This method demonstrates a high diagnostic yield with a low complication rate.
- The use of a simple, commercially available drill offers a potentially cost-effective and accessible alternative for bone biopsy procedures.