Related Experiment Video
Updated: Aug 6, 2026

Laminotomy for Lumbar Dorsal Root Ganglion Access and Injection in Swine
Published on: October 10, 2017
Radiation exposure to the physician performing fluoroscopically guided caudal epidural steroid injections
K P Botwin1, E D Freeman, R D Gruber
1Florida Spine Institute, Clearwater, FL 33765, USA.
Abstract:
This study was designed to investigate radiation exposure to a physician performing fluoroscopically guided caudal epidural steroid injections. The prospective study design included 100 consecutive fluoroscopically guided caudal epidural steroid injections performed on patients with radiculitis from either herniated nucleus pulposus or lumbar spinal stenosis. Radiation exposure was monitored with the assistance of a radiological technologist (RT) who allocated four dosimetry badges to all physicians performing fluoroscopically guided caudal epidural steroid injections on consecutive patients being treated for radicular pain. The badges were placed on the ring finger, glasses and both the inside and outside of the lead apron worn by the physician. In addition, the RTs also wore a marked badge outside his/her lead apron. A control badge was placed 67 inches away from the fluoroscopy table, and a second control badge was located in a desk over 500 feet away from the procedure, to monitor ambient radiation. The average fluoroscopy time per procedure was 12.55 seconds. The average/cumulative exposure per procedure was 4.10/410 mREM at the "ring" badge, 2.47/247 mREM at the "glasses" badge, 3.98 /398 mREM at the "outside apron" badge and 0.15/15 mREM at the "inside" apron; no radiation was detectable at the "outside room" control badge. The RT's average exposure during these procedures was below the limit of detectability. Radiation exposure to the physician needs to be considered and minimized in the performance of spinal interventional procedures. Our study demonstrates that radiation exposure to the physician performing fluoroscopically guided caudal epidural steroid injections is well within safety limits when he/she adheres to proper technique.
Related Concept Videos
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Local Anesthetics: Clinical Application as Spinal Anesthesia
Imaging Studies VII: Vascular Imaging
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...