Digitized infrared segmental thermometry: time requirements for stable recordings
Related Experiment Video
Updated: Aug 6, 2026

Infrared Thermography for the Detection of Changes in Brown Adipose Tissue Activity
Published on: September 28, 2022
Richard A Roy1, Jean P Boucher, Alain S Comtois
1Université du Québec à Trois-Rivières, Module Chiropratique, CP 500, Trois-Rivières, Québec, Canada.
Objectives:
Digitized infrared segmental thermometry (DIST) is a method for measuring and recording skin surface body temperatures. The project evaluated the required length of time for patients to acclimatize their core body temperature to ambient conditions to obtain stable DIST readings.
Methods:
Seventeen subjects were allowed a 20-minute acclimatizing period in a temperature-controlled room. The bilateral DIST temperature was measured with thermistors in combination with infrared cameras (IRCs) at the C4 and L4 levels. All IRC temperatures were recorded after a 20-minute stabilization period. The room temperature and relative humidity were recorded throughout all trials. The acclimatization trend was computed from the 20- to 24-minute period for the IRCs, and the acclimatization trend was computed continuously for a total of 30 minutes (at 2-minute intervals) for 5 days.
Results:
We discovered a stabilization trend in the early trial stages, with the thermistor recordings between 8 and 16 minutes. The IRC trend was also conclusive for the core temperature requirements.
Conclusions:
This study determined a core body temperature acclimatization trend tested among patients using thermistor recordings in a controlled environment. Based on these findings, we recommend acclimatization in a temperature- and humidity-controlled environment for a minimum 8-minute period, followed by an 8-minute maximum recording period with the patient in a prone position to obtain accurate DIST recordings.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
IR Spectrometers