Related Experiment Video
Updated: Aug 6, 2026

Clinical Imaging of Microwave Mammography
Published on: November 14, 2025
A test of performance of breast MRI interpretation in a multicentre screening study
Ruth Warren1, Carmel Hayes, Linda Pointon
1Department of Radiology, Addenbrooke's Hospital, Cambridge CB2 2QQ, UK.
Objectives:
The aim of this study was to assess the consistency and performance of radiologists interpreting breast magnetic resonance imaging (MRI) examinations.
Materials And Methods:
Two test sets of eight cases comprising cancers, benign disease, technical problems and parenchymal enhancement were prepared from two manufacturers' equipment (X and Y) and reported by 15 radiologists using the recording form and scoring system of the UK MRI breast screening study [(MAgnetic Resonance Imaging in Breast Screening (MARIBS)]. Variations in assessments of morphology, kinetic scores and diagnosis were measured by assessing intraobserver and interobserver variability and agreement. The sensitivity and specificity of reporting performances was determined using receiver operating characteristic (ROC) curve analysis.
Results:
Intraobserver variation was seen in 13 (27.7%) of 47 of the radiologists' conclusions (four technical and seven pathological differences). Substantial interobserver variation was observed in the scores recorded for morphology, pattern of enhancement, quantification of enhancement and washout pattern. The overall sensitivity of breast MRI was high [88.6%, 95% confidence interval (CI) 77.4-94.7%], combined with a specificity of 69.2% (95% CI 60.5-76.7%). The sensitivities were similar for the two test sets (P=.3), but the specificity was significantly higher for the Manufacturer X dataset (P<.001). ROC curve analysis gave an area under the curve of 0.85 (95% CI 0.79-0.92)
Conclusions:
Substantial variation in all elements of the scoring system and in the overall diagnostic conclusions was observed between radiologists participating in MARIBS. High overall sensitivity was achieved with moderate specificity. Manufacturer-related differences in specificities possibly occurred because the numerical thresholds set for the scoring system were not optimised for both equipment manufacturers. Scoring systems developed on one equipment software may not be transferable to other manufacturers.
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies IV: Magnetic Resonance Imaging
Magnetic Resonance Imaging