Numerical implementation of viscoelastic blood flow in a simplified arterial geometry
1Departamento de Ingeniería Mecánica, Tecnologías de Fabricación, Universidad Politécnica de Cataluña-ETSEIB, Av. Diagonal 647, 08028 Barcelona, Spain. hernan.gonzalez@upc.edu
Abstract:
The influence of the non-Newtonian stress-strain relation of blood on the oscillatory shear index (OSI) and mean wall shear stress (WSS) are described. The unsteady linear 1D momentum equation is solved for a viscoelastic fluid, with six elements of the Maxwell type and one dashpot element connected in parallel. A novel numerical algorithm is described which uses the upwind finite difference method to solve the equation of momentum. Results obtained by using a finite difference approach show significantly higher values of OSI when blood is assumed to be a viscoelastic fluid compared with those of simplified Newtonian fluid model. The calculation of OSI in human normal conditions for the Newtonian fluid differs in 12% (if alpha=0.02) from the results obtained from using the viscoelastic model.
More Related Videos
06:18Intravascular Ultrasound Image-Based Finite Element Modeling Approach for Quantifying In Vivo Mechanical Properties of Human Coronary Artery
Published on: December 6, 2024
07:30In Vitro Model of Physiological and Pathological Blood Flow with Application to Investigations of Vascular Cell Remodeling
Published on: November 3, 2015
Related Concept Videos
Applications of Integration to Find Blood Flow
Viscosity of Fluid
Blood Flow
Navier–Stokes Equations
Bernoulli's Equation for Flow Along a Streamline
Newtonian Fluid: Problem Solving
A velocity gradient forms within the fluid when a Newtonian fluid is placed between two parallel plates, with...