Related Experiment Video
Updated: Jul 20, 2026

Parameterizing V-notch Weir Equations for Flow Monitoring in a Drainage Control Structure
Published on: April 25, 2025
A different approach for predicting reaeration rates in gravity sewers and completely mixed tanks
Ori Lahav1, Assaf Binder, Eran Friedler
1Division of Environmental, Water and Agricultural Engineering, Faculty of Civil and Environmental Engineering, Technion-Israel Institute of Technology, Haifa, Israel. agori@tx.technion.ac.il
Abstract:
A new semiempirical approach is presented for predicting air-to-water oxygen transfer rates in mixed tanks and gravity sewers, using methods adopted from mixing theory. First, a flocculation unit was used to impart selected mean velocity gradients (G) into a completely mixed tank, from which oxygen was first removed, and dissolved oxygen concentrations were measured with time. Regression analysis was used to fit the rate of oxygen transfer equation against G. The reaeration rate in completely mixed reactors was found to be proportional to G2 (R2 = 0.987). Subsequently, G was linked to headloss in sewers, and the equation was calibrated using a slope-adjustable, 27-m-long, gravity-flow, experimental sewer (internal diameter, D = 0.16 m). Here, the reaeration rate was proportional to G1 (R2 = 0.981). The equation was compared with existing oxygen transfer models and validated against experimental data from the literature, to which the overall mass transfer coefficient for oxygen, K(L)a, derived by the new approach, conformed well.
Related Concept Videos
Typical Model Studies
Design Example: Design of an Irrigation Channel
Rapidly Varying Flow
Weir: Problem Solving
Gradually Varying Flow
Conservation of Mass in Fixed, Nondeforming Control Volume
In the case of a sewer pipe, which can be modeled...