Original Experimental Approach for Assessing Transport Fuel Stability
Published on: October 21, 2016
Inverse gas chromatography used to study lubricating oil oxidation mechanism via changes in Kovats and Flory-Huggins
Nagy E Mostafa1, Elham A Eissa
1Egyptian Petroleum Research Institute, Cairo. research@epri.sci.eg
Abstract:
Inverse gas chromatographic technique (IGC) was attempted as a new approach to follow the chemical changes that occur during lubricating base oil oxidation. Three groups of the oxidized base oils were prepared at different oxygen flow rates, periods and temperatures according to IP48 method. The corrected retention volumes (VR) were calculated for a series of selected test solutes possessing different functional groups on the oxidized base oils used as stationary phases. Kovats retention index (I), Flory-Huggins interaction parameter (Kinfinity1,2), and partial molar free energy of solution (deltaGinfinityL), were calculated for the given test solutes from their VR. The relationships between the I values and the oxidation variables were plotted and discussed. The obtained results were confirmed by potentiometric titration. The study reveals that the magnitudes of variation of I, Kinfinity1,2 or deltaGinfinityL retention parameters depend on the oxidation degree of the base oil. Large differences between the I values permit discrimination between the different oxidation steps.
More Related Videos
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...