Related Experiment Video
Updated: Jul 20, 2026

A Generalized Method for Determining Free Soluble Phenolic Acid Composition and Antioxidant Capacity of Cereals and Legumes
Published on: June 10, 2022
Determination of phenolic compounds in fennel by HPLC and HPLC-MS using a monolithic reversed-phase column
Mitja Krizman1, Dea Baricevic, Mirko Prosek
1Laboratory of Food Chemistry, National Institute of Chemistry, Hajdrihova 19, 1000 Ljubljana, Slovenia. mitja.krizman@ki.si
Abstract:
A reversed-phase high-performance liquid chromatography (HPLC) method for analyzing phenolic compounds in fennel (Foeniculum vulgare) has been developed. The use of a monolithic column with short dimensions in combination with optimized chromatographic conditions allows over 100 samples per day to be analyzed. Chromatographic parameters such as column temperature and injection volume, were found to be crucial in obtaining adequate selectivity and resolution, consequently allowing short run times. The method was validated for the major phenolic compounds present in fennel plant material: 3-O-caffeoylquinic acid (3-CQA), chlorogenic acid, 4-O-caffeoylquinic acid (4-CQA), eriocitrin, rutin, miquelianin, 1,3-O-dicaffeoylquinic acid (1,3-diCQA), 1,5-O-dicaffeoylquinic acid (1,5-diCQA), 1,4-O-dicaffeoylquinic acid (1,4-diCQA) and rosmarinic acid. The limits of detection (LOD) and the limits of quantitation (LOQ) ranged from 0.05 to 1.0 microg/mL and from 0.15 to 2.5 microg/mL, respectively. With some adaptation, the extraction procedure could be even less invasive, which is useful in screening work.
More Related Videos
06:25Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
14:39Semi-Targeted Ultra-High-Performance Chromatography Coupled to Mass Spectrometry Analysis of Phenolic Metabolites in Plasma of Elderly Adults
Published on: April 22, 2022
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
High-Performance Liquid Chromatography: Instrumentation
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...