Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Targeted multidimensional gas chromatography for the quantitative analysis of suspected allergens in fragrance
Michael S Dunn1, Natalie Vulic, Robert A Shellie
1Australian Centre for Research on Separation Science, School of Applied Sciences, RMIT University, GPO Box 2476V, Melbourne 3001, Australia.
Abstract:
Two approaches are described and compared for the analysis of suspected allergens (SAs) in fragrance products, which are defined by the Scientific Committee of Cosmetics and Non-Food Products (SCCNFP). The first consists of a comprehensive two-dimensional gas chromatography (GC x GC) experiment using both a "conventional" non-polar/polar column combination and an "inverse" polar/non-polar column set. The second approach uses a targeted multidimensional gas chromatography (MDGC) system employing a Deans type pneumatic switch and a longitudinally modulated cryogenic system (LMCS). It was found that the conventional and inverse column sets complement each other well, providing identification of SAs present. Compounds well retained on the second dimension of one column set were the first to be eluted from the other. In some instances SAs co-eluting with matrix components on the second dimension for a given column set were clearly resolved on the other, although this has the disadvantage of requiring two analytical runs. Targeted MDGC with a non-polar/polar column set, successfully separated all SAs identified within a fragrance product. The instrument is set up in a similar fashion to a GC x GC system though with longer second dimension ((2)D) column, a cryogenic trap at the beginning of the second column, and a pneumatic switch coupling both columns. The data are easier to process than for a GC x GC experiment. The targeted MDGC method has the capacity to deliver far greater efficiency to targeted regions of a primary separation than a GC x GC experiment, whilst still maintaining overall run times similar to those of a conventional one-dimensional (1D) GC experiment. Cryogenic focussing at the beginning of the (2)D column delivers enhanced sensitivity, accurate (2)D retention times and narrow peak widths; these are responsible for an increased resolution obtained from the fast, relatively short (approximately 5 m) (2)D column. The two column set GC x GC analysis provided a quick and effective means to qualitatively determine the presence of six SAs in a commercially available air freshener, however all were not adequately resolved from matrix components. In contrast, quantitation was straightforward using the targeted MDGC method.
More Related Videos
05:22Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.