Related Experiment Video
Updated: Jul 20, 2026

Fabrication and Characterization of a Conformal Skin-like Electronic System for Quantitative, Cutaneous Wound Management
Published on: September 2, 2015
Development and testing of a wearable Integrated Thermometer sensor for skin contact thermography
1Dipartimento di Tecnologie e Salute, Istituto Superiore di Sanità, Viale Regina Elena, 299-00161 Roma, Italy. dgiansa@iss.it
Abstract:
The need of wearable devices for the thermal monitoring is rising. These devices could be used during medical continuous monitoring, for instance in breast cancer investigation, or for the monitoring of vascular, dermatological and rheumatic disorders, in viability studies, and during physical exercises. We had designed and constructed a wearable device for skin-contact thermography that uses integrated silicon sensors. The bench test validation was performed by means of a commercial oven for the static bench test and a properly designed phantom for the dynamic bench test. The thermal resolution was better than 0.03 degrees C and the spatial resolution equal to 1.6 x 10(-5)m2. We then investigated its performance in a medical application, suited for clinical testing, in which volunteers were subject to a maximal rate of thermal skin variation equal to 3.1 degrees C/0.25 h. We also compared the results with those obtained by means of an Infrared-Digital-Video-Camera. Results of the comparison showed a maximal error always lower than 0.14 degrees C.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...