Voltammetry and quantification of the contraceptive drug norethisterone in bulk form and pharmaceutical formulation

M M Ghoneim1, A M Abushoffa, Y I Moharram

  • 1Chemistry Department, Faculty of Science, Tanta University, 31527 Tanta, Egypt. mmghoneim@usa.net

Related Concept Videos

Coulometry: Overview01:00

Coulometry: Overview

Coulometry is one of the rapid, most accurate, and precise analytical techniques that determine the quantity of an analyte by measuring the electrical charge needed for its complete electrolysis without using any analytical standards. The total charge passed during electrolysis correlates with the analyte amount by Faraday's laws of electrolysis. For accurate coulometric measurements, a charge equal to Faraday's constant multiplied by the number of electrons involved in the relevant...
Voltammetry: Overview01:20

Voltammetry: Overview

Voltammetry is an electroanalytical technique in which the current flowing through an electrochemical cell is measured as a function of applied potential, typically under conditions of concentration polarization. The technique provides valuable information about redox-active species, and the current response is plotted as a voltammogram.
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetric Techniques: Cyclic Voltammetry01:10

Voltammetric Techniques: Cyclic Voltammetry

Cyclic voltammetry (CV) is an electrochemical technique used to investigate the redox properties of a chemical species. It involves measuring the current response of an electrochemical cell as a function of the applied potential. The setup for cyclic voltammetry typically consists of a working electrode, a reference electrode, and a counter electrode—all immersed in an electrolyte solution. The working electrode is where the redox reaction of interest occurs, while the reference electrode...
Drug Concentrations: Measurements01:23

Drug Concentrations: Measurements

Drug concentration is the quantity of a drug present in a biological sample. Measuring drug amounts in biological samples allows the clinician to understand how a drug is absorbed, distributed, metabolized, and excreted. Samples can be obtained through invasive or non-invasive methods. Invasive techniques involve surgical or parenteral interventions to gather blood, cerebrospinal fluid, or tissue biopsy. Conversely, non-invasive approaches provide samples like urine, feces, and saliva.
Plasma —...
Drug Dissolution: Requirements and Profile Comparison01:14

Drug Dissolution: Requirements and Profile Comparison

The acceptance criteria for dissolution profile data are anchored in Q values, representing the percentage of drug dissolved within a specified period. This assessment unfolds in three stages:First Stage: The test passes if all six drug dosage units are equal to or greater than Q plus 5%; otherwise, the sample proceeds to the second stage.Second Stage: The average of twelve units must be equal to or greater than Q, with no unit falling below Q - 15% to pass; if not, it progresses to the final...
Clinically Relevant Drug Product Specifications: Methods of Establishment01:29

Clinically Relevant Drug Product Specifications: Methods of Establishment

Product specifications define the acceptable quality of a pharmaceutical product by ensuring identity, purity, potency, and strength. These specifications serve as benchmarks during development, manufacturing, and post-approval quality control. Clinically relevant specifications are particularly important because they directly relate to a drug's safety and efficacy in clinical use.Dissolution studies are critical biopharmaceutic tools that link in vitro behavior to in vivo performance. They...