[Comparison of noise equivalent count rate and image quality for two-dimensional and three-dimensional PET scans]
Keiichi Matsumoto1, Keiji Shimizu, Keishi Kitamura
1Division of Molecular Imaging, Department of Image-based Medicine, Institute of Biomedical Research and Innovation.
Abstract:
The aim of this study was to investigate the correlation between noise equivalent count (NEC) rates and the signal-to-noise ratio (S/N) in reconstructed images. The NEC rates were determined using uniform 20 cm and 70 cm tall, 20 cm diameter cylinders filled with 11C. The phantoms were scanned in both two-dimensional and three-dimensional modes. The reconstructed image noise was evaluated using FBP and OSEM algorithms (4 iterations and 8 subsets). The images were filtered to a final image resolution of 6.5 mm. From the reconstructed image sets, averages and standard deviations of images were generated, from which the average image S/N (=average/standard deviation) was calculated within an 18 cm central ROI. The S/N of a central slice and an end slice was compared with the NEC. The NEC was found to have a linear relationship to the image S/N of all slices, depending on differences in noise properties specific to the reconstruction algorithm. In two-dimensional mode, although the image S/N of the central slice and the edge slice showed a linear relationship with the NEC, in three-dimensional mode, the S/N of the central slice did not show a relationship with the NEC. The linear relationship was also found in both two- and three-dimensional acquisition modes, as well as for the different activity distributions. These results indicate that the NEC is not only a measure for comparing the count rate performance of imaging systems. However, an absolute evaluation is impossible to depend on reconstruction algorithm, slice number, and phantom type.
More Related Videos
08:02Novel Quantification Protocol for Cardiovascular Calcification Progression Using Longitudinal MicroPET/MicroCT Images
Published on: November 15, 2024
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...