Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Automatic detection of bubbles in the subclavian vein using Doppler ultrasound signals
Kadir Tufan1, Ahmet Ademoglu, Emre Kurtaran
1Department of Technical Programs, Vocational School of Fatih University, Istanbul, Turkey.
Introduction:
It is possible to detect venous gas bubbles by listening to the Doppler audio signals. However, a serious disadvantage of the audio evaluation is the inability of continuous monitoring and the inter-rater agreement. Several researchers have worked on the automated detection of emboli, but no current system has the required sensitivity and specificity for clinical use.
Method:
We developed software that integrated frequency filtering, processing, and detection phases of microemboli into a graphical user interface. The detection algorithm consists of a rule-based criterion with a user-defined threshold sliding in-time axis that estimates the duration of the embolic event. Subclavian Doppler audio recordings obtained from a high altitude diving expedition were analyzed using digital filtering and non-linear operator combinations of the software. The data set includes 43 embolic events in 9 recordings from 4 different subjects.
Results:
It was determined that embolic signals are best differentiated from the background signal at the 4500-8000-Hz frequency band. By using the non-linear "Teager Energy Operator", embolic signals were amplified against their background and a high level of sensitivity and specificity was obtained (83.7% and 97.3%, respectively). The duration of the detected emboli was estimated as 12.17 +/- 4.36 ms (mean +/- SD).
Discussion:
The optimal frequency band for the detection of subclavian emboli is significantly higher than previous findings for the transcranial site. The duration output of the software can be used to estimate the size and the composition of emboli. Successful integration of the software into an ambulatory detection system may provide important site-specific bubble size distribution data for decompression modeling.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...