Related Experiment Video
Updated: Jul 19, 2026

Interventional Diagnostic Procedure: A Practical Guide for the Assessment of Coronary Vascular Function
Published on: March 15, 2022
Distal embolic protection during percutaneous coronary intervention in patients with acute coronary syndromes: the
Antonio L Bartorelli1, Tian-Hai Koh, Francesco Di Pede
1Institute of Cardiology, University of Milan, Centro Cardiologico Monzino, Milan, Italy. antonio.bartorelli@ccfm.it
Objective:
To assess the safety and feasibility of the GuardWire system as an embolic protection device during percutaneous coronary intervention (PCI) in acute coronary syndromes (ACS).
Background:
Distal embolization occurs in approximately 15% of patients after primary angioplasty and is associated with reduced myocardial reperfusion, more extensive myocardial damage and a poor prognosis. Distal embolic protection could reduce the rate of embolic complications and improve outcome.
Methods:
329 patients (mean age 60+/-12 years) were included: 278 (84.5%) with ST-elevation myocardial infarction (STEMI), 50 (15.2%) with unstable angina/non-STEMI and 1 (0.3%) with post-infarction angina. Primary endpoint was the incidence of major adverse cardiac events (MACE) at 30 days. Secondary endpoints were the magnitude of ST-segment resolution at 90 and 180 min post-procedure, myocardial blush grade, and angiographically visible distal emboli.
Results:
The GuardWire system was successfully positioned in 99% of patients. Complete ST-elevation resolution (>70%) was observed in 28.5% immediately post-procedure, and in 35.4% and 41.6% at 90 and 180 min post-procedure. TIMI-3 flow grade was achieved by 89.8% of patients after intervention and mean corrected TIMI frame count was 20.2+/-13.2. Grade-3 myocardial blush was seen in 47.7% of patients and distal emboli were angiographically visible in 7.4%. Incidence of MACE at 30 days was 3.3% (death 1.2%; Q-wave MI 0.3%; non-Q-wave MI 0.3%; coronary artery bypass graft 0.6%; repeat PCI 0.9%).
Conclusion:
The GuardWire system was successfully positioned in nearly all patients without complications. The use of this embolic protection device in ACS patients undergoing PCI was associated with low rates of distal embolization and 30-day MACE.
Related Concept Videos
Peripheral Artery Disease III: Interprofessional Care
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Acute Coronary Syndrome IV: Interprofessional Care
Acute Coronary Syndrome III: Diagnostic Studies
Coronary Artery Disease V: Interprofessional Care
Antiplatelet Drugs: Prostaglandin Synthesis, P2Y12 and Glycoprotein IIb/IIIa Inhibitors
Prostaglandin synthesis inhibitors, exemplified by the widely known aspirin, wield their power by irreversibly acetylating...
