Electrostatic potential energy within a protein monitored by metal charge-dependent hydrogen exchange

Janet S Anderson1, David M LeMaster, Griselda Hernández

  • 1Department of Chemistry, Union College, Schenectady, NY 12308-3107, USA.

Biophysical Journal
|October 3, 2006
PubMed

Related Concept Videos

Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at the...
Two-dimensional Gel Electrophoresis01:22

Two-dimensional Gel Electrophoresis

Two-dimensional gel electrophoresis is a high-resolution protein separation method first introduced by O' Farrell and Klose in 1975. This method involves protein separation by two dimensions, mass and charge, making it more accurate than one-dimensional gel electrophoresis.
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as  cells...
Electrochemical Systems01:24

Electrochemical Systems

Electrochemical systems provide a fascinating insight into the dynamic interplay of charged species within various phases. One notable example is the interaction between a membrane permeable to K⁺ ions but not to Cl⁻ ions, separating an aqueous KCl solution from pure water. As K⁺ ions diffuse through the membrane, they generate net charges on each phase, leading to a potential difference between them.Similarly, when a piece of Zn is immersed in an aqueous ZnSO₄ solution, the Zn metal, composed...
Capillary Electrophoresis: Instrumentation01:20

Capillary Electrophoresis: Instrumentation

Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...